Rosemount 3051L2AA0FD11AA - Level Transmitter
Ordering Information
- Transmitter type¹: 3051L - Level Transmitter
- Pressure range: 2 - -250 to 250 inH20 (-621,60 to 621,60 mbar)
- Transmitter output²: A - 4–20 mA with digital signal based on HART protocol
- Process connection size, diaphragm material (high side): A - 3-in./DN80; 316L SST
- Seal extension length (high side): 0 - None, flush mount
- Mounting flange size, rating, material (high side): F³ - 3-in.(Size); ANSI/ASME B16.5 Class 150(Rating); 316 SST(Material)
- Seal fill fluid (high side): D
- Low pressure side: 11³ - Gage (Configuration); SST (Flange adapter); 316L SST (Diaphragm); Silicone (Sensor fill fluid)
- O-ring: A - Glass-filled PTFE
- Housing material: A - Aluminium; 1/2-14 NPT (Conduit entry size)
NOTE:
Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Product Datasheet: Rosemount DP Level Transmitter and 1199 Seal Systems